LATINA VOR/DME (LAT) on 111.20 MHz/CH 49X has defined operational coverage limitations: for the VOR, not usable beyond 15 NM on radial 018; between 29–35 NM on radial 024 it requires 14000 ft; at 25 NM, sector-specific MRAs apply (005°–110° NU, 110°–130° MRA 5000 ft, 130°–290° MRA 2500 ft, 290°–330° MRA 5000 ft, 330°–005° MRA 10000 ft). For the DME, not usable beyond 15 NM on radial 018 and beyond 17 NM on radial 024; at 25 NM, sector-specific limitations mirror the VOR (NU or MRAs as listed). Reference AIP AD 2 LIRF 1-25, column 7.